5Pcs DC 12V Delay Relay Shield NE555 Timer Switch Adjustable Module 6 2CM5Pcs DC 12V Delay Relay Shield NE555 Timer Switch Adjustable Module 6 2CM5Pcs DC 12V Delay Relay Shield NE555 Timer Switch Adjustable Module 6 2CM5Pcs DC 12V Delay Relay Shield NE555 Timer Switch Adjustable Module 6 2CM5Pcs DC 12V Delay Relay Shield NE555 Timer Switch Adjustable Module 6 2CM5Pcs DC 12V Delay Relay Shield NE555 Timer Switch Adjustable Module 6 2CM5Pcs DC 12V Delay Relay Shield NE555 Timer Switch Adjustable Module 6 2CM5Pcs DC 12V Delay Relay Shield NE555 Timer Switch Adjustable Module 6 2CM5Pcs DC 12V Delay Relay Shield NE555 Timer Switch Adjustable Module 6 2CM5Pcs DC 12V Delay Relay Shield NE555 Timer Switch Adjustable Module 6 2CM
Right

Buy More... Get Lower Prices
Retail Price for $13.73 
Quantity:



$10.59 

Shipping Cost: FREE SHIPPING to
United States via FPX--Singapore Parcel Postal 
 

Yes! We Ship To  us
.
Delay Relay Shield NE555 Timer Switch
Delay Relay Shield NE555 Timer Switch
$10.59 
.
  • The delay time is adjustable, (0 to 10 seconds).
  • Increasing the potential can increase the delay time.
  • Increasing the capacitor C1 can increase the delay time.
  • With input power indicator.
  • With relay indicator.
  • Can control AC 220V / 10A about equipment (Maximum control equipment 2000W).
  • With freewheeling protection relay.
.

Description:

Item name: tool

Module based on : NE555 chip

Delay module : Delay connect module

Input voltage : DC12V

Control voltage : AC 0 - 250V/max. 10A, DC 0 - 30V/max. 10A

The operating voltage : 12V DC

Max. load : 2200W

Size : Approx 6 x 2cm

Package includes:

5 x Delay Relay Modules

Notes:

Power relay delay pull. Specifically : 12v power supply to the relay, the relay will not immediately sucked and status relay outputs are: normally open disconnected public, normally closed and public conduction; wait until the delay 1-10s (adjustable), the relay suction and, this time, the relay output status is: normally open and public conduction, normally closed and public disconnected; as long as Uninterrupted power module, this state will remain.
The delay time formula : T = 1.1RC. For example : a resistor capacitor 100uf 100K T = 1.1 x 100000 x 0.0001 = 11 seconds.

The colors deviation might differ due to different monitor settings.

.